va亚洲va欧美va国产综合-va在线播放-va在线观看-va在线视频-vr成人片在线播放网站-v天堂中文在线

 
 
 
ADD: NO.51-46 South Gate Waidajie, DanYang City Jiangsu, China
TEL: 0511-86522592 86525322
FAX :0511-86519375
 
 
 
 
 
 
 
Solid state Capacitor
Series
Feature
Temperature range℃
(V.DC)
Voltage range
(V)
Capacity range(μF)
Leakage(μA)
Life
Standard
-55~+105
2.5~25
10 ~ 3500
≤0.2CV
2000h
Low ESR
-55~+105
2.5~25
22 ~ 2700
≤0.2CV
2000h
super low ESR
-55~+105
2.5~10
220 ~ 3500
≤0.2CV
2000h
High Voltage
-55~+105
30~100
4.7 ~ 400
≤0.2CV
5k~10k h
super High Voltage
-55~+105
160~250
1.8 ~ 330
≤0.2CV
5k~10k h
125℃ Guaranteed
-55~+125
2.5~100
47 ~ 2700
≤0.2CV
2000h
135℃ Guaranteed
-55~+135
35~100
4.7 ~ 400
≤0.2CV
1000h
Low leakage
-55~+105
2.5~100
15 ~ 680
≤150uA
2000h
Long life
-55~+105
2.5~25
100 ~ 2700
≤0.2CV
5000h
Standard
-55~+105
2.5~100
22 ~ 2700
≤0.2CV
2k~10k h
 
Product development series
 
Differences from other capacitors
 
Structure of solid capacitors
 
Characteristics
 

 
7.Instantaneous charge and discharge
Instantaneous charging and discharging may cause leakage current of solid capacitor larger or even short defect:
1)Therefore, it is necessary to design a protective circuit in the following situations Impact current greater
than 10A.
2)Impact current greater than 10 times allowable max ripple current value.
In addition, when testing the product leakage current, set a 1KΩ protection resistor.

8.Prohibited circuits
Due to welding heat and mechanical stress during transportation, the leakage current of capacitor may increase. Please prohibit the following circuit designs.
1)High current and voltage holding circuit.
2)Coupling circuit.
3)Time constant circuit.

9.Circuit design
1)As electrical characteristics of capacitor change following the temperature and frequency changing, Please confirm this change before designing.
2)When connecting more than 2 capacitors in parallel, consider the current balance of them in the circuit design.
3)When two or more capacitors are connected in series, it is possible that capacitor overloads the voltage due
to differences in the loading voltage. Please consult us when using it.
4)Do not install heating parts around the capacitor or on the back of the printed wiring panel.

10.PCB design
Do not install solid capacitors around or on the heat source assemblies.
The diameter and spacing of mounting holes on PCB should match the diameter and pitch of capacitor lead.

11.Parallel circuit
When a solid capacitor is connected in parallel with another capacitor (liquid), because the solid capacitor has very low ESR, a large ripple current may be applied to it. In this case, please carefully select the solid capacitor.

12.Insulation
The insulating coating outside the aluminum can of solid capacitor is not absolutely insulated. In addition, the aluminum can and negative lead are not insulated. When installing, please ensure that the aluminum can. positive and negative leads and PCB printing drawings are completely separated.

13.Restrictions on the working environment
1)Where water, salt water, oil can be dropped directly, and circuit boards that are prone to contraction, use is prohibited.
2)When harmful gases(H2S, sulfuric acid, nitric acid, ammonia, hydrochloric acid, etc.) are concentrated, use is prohibited.
3)Where ultraviolet, radioactive, ozone, etc. are radiated, use is prohibited.

14.Common failure mode
1)Accidental failure
Mainly caused by short defect of circuit, when current in the short circuit exceeds 1A, inner temperature of
capacitor will increase, and the internal pressure will increase, the sealing rubber will be raised or even opened,
then the capacitor will release harmful gas. At this point, it need to disconnect the circuit immediately and leave
this situation. In addition, overvoltage usage, ultra-high temperature usage, and excess rated ripple current usage,
will all lead to early failure or even short defect of the product.
2)Life failure
After a long period of useing, the characteristics of solid capacitor will decay, such as capacity drop, ESR rise,
etc.. When the service time exceeds the rated life, the characteristics of capacitor will deteriorate, which may lead
to the formation of an open circuit for electrolyte insulation.

 
Installation attentions
1.Preparation for installation.
1)Please do not reuse solid capacitors that have been installed and used.
2)Make sure that the capacitor to be installed does not exceed the storage period.
3)Please do not touch the pins of solid capacitor directly by hand.
4)Do not use a conductor to connect the positive and negative pins of capacitor. Do not let the capacitor contact
the conductive solution.
5)Confirm the capacity and working voltage of installed capacitor.
6)Please note the polarity of the capacitor.
7)Please prevent the capacitor from falling to the ground, otherwise do not use.
8)Please do not use the capacitor which body is pressed and deformed.
9)Please check that the pin of capacitor matches the PCB hole.
10)Please control the inserting strength and vibration strength.
11)Do not apply additional external force to the pins or body of capacitor .
12)When welding, please control the welding temperature and time, any of them over standard will cause leakage
current of capacitor increase.
13)When welding, make sure that hot components such as soldering tin and soldering iron are not in normal
contact with capacitor pins or body.

2.Attentions after welding
1)After welding, do not use external force to tilt, bend, twist capacitor pins or body.
2)Please do not grab the capacitor body to move the PCB.
3)When stacking welded PCB, prevent contact and friction between capacitor and capacitor, or with other
components.
4)Do not let the solid capacitor welded to PCB withstand any external force.
5)When removing the solid capacitor from the circuit board with a soldering iron, it is recommended that the
removed capacitor be scrapped to avoid the affects of stress and overheating.
6)Do not touch the head of the welding iron to the solid capacitor body. Even the pin part can not stay in .contact
7)The leakage current may increase after the solid capacitor is welded, and the leakage current will gradually
decrease after the voltage is applied.

3.Electric iron welding

4.Reflowwelding

 
 
Storage Conditions and Environmental Requirements
1)Do not store solid capacitors in high temperature and high humidity. It is recommended to store temperature:
5-35 °C, humidity <75%.
2)To ensure solid capacitors favorable soldering performance, please do not open the packages and storage
period should not exceed 18 months.
3)For unpackaged products that have not been used at one time, please put them back into the bag and seal them.
The storage period for each type of product is as follows.
4)With the extension of storage time, the leakage current of the solid capacitor will increase. It can be repaired by charging the rated operating voltage (DC voltage) for 1 hour at 60-70 °C, and the capacitor should be connected in series with 1KΩ to protect the resistor.
5)Because solid capacitors contain some solid organic matter, metal materials and resin materials, please treat
them as work waste.
6)Our products and using materials are in compliance with EU restrictions on hazardous substances:
 
Product markinginstructions
 
Product code description
 
Standard product packing

 
Cutting product package

 
Taping product package

 
SMD product package
 
 
 
 
 
 
 
 
 
copyright:© Jiangsu Fala Electronics Co., Ltd
TEL:86-511-86522592  FAX:86-511-86519375  ADD:NO.51-46 South Gate Waidajie, DanYang City Jiangsu, China
MAIL:fala@chinafoai.com,market@chinafoai.com;URL:m.bbpress.net.cn
 

主站蜘蛛池模板: 日韩不卡在线 | 国产成人精品一区二三区2022 | 雅虎日本免费一区二区三区 | 午夜影院网页 | 久久福利资源网站免费看 | 热久久精品免费视频 | 久久久久久尹人网香蕉 | 久草首页在线观看 | 思99热精品久久只有精品 | 青青青永久免费视频 | 四虎永久在线精品国产免费 | 一本色道久久88加勒比—综合 | 国产美女久久久 | 久久精品国产一区二区小说 | 99爱网站| 久久刺激 | 好好的日com欧美 | 香蕉视频网站免费观视频 | 免费在线黄色网址 | 国产中文字幕在线免费观看 | 一区二区三区在线 | 全部免费国产潢色一级 | 欧美成人精品久久精品 | 免费黄色影院 | 日本一区二区在线播放 | 亚洲日本一区二区三区 | 春暖花开亚洲 | 五月亭亭免费高清在线 | 精品无码久久久久国产 | 精品一区二区三区四区 | 国产二区视频 | 夜夜嗨影院 | 国产真实一区二区三区 | 亚洲综合图片人成综合网 | 日韩中文字幕视频 | 澳门一级特黄录像免费播黄 | 女人18毛片a级毛片免费 | 桃色婷婷 | 亚洲国产欧美国产第一区二区三区 | 成人私人影院在线观看网址 | www.亚洲视频 |